Shenzhen, China · Factory direct since 2007 5,000 m² plant · Every process in-house · Ships worldwide
+86 755 2796 7043 Mon–Fri 09:00–18:00 GMT+8
EN Get a Quote

Compliance

ESD acrylic: what it is, where it is required, and how to specify it

Standard acrylic holds a charge of several kilovolts and will not let it go. Near exposed electronics that is a failure mode, and it is invisible until a board fails test.

~1,400 words · 7 min read · Updated 2026-11-10

Electrostatic discharge damages components that look fine and fail later, which makes it one of the more expensive failure modes in electronics assembly. Standard acrylic is a good insulator: it generates charge easily and holds it, so a guard panel or a cover near bare boards is a risk that nobody can see.

The resistivity scale

Material classification by surface resistivity
ClassSurface resistivityBehaviourTypical material
Conductive10^2 to 10^5 ohm/sqCharge drains almost instantlyCarbon-loaded plastics, metal
Static dissipative10^6 to 10^9 ohm/sqCharge drains in a controlled timeESD acrylic, ESD PVC, ESD PC
InsulativeAbove 10^11 ohm/sqCharge is heldStandard acrylic, glass, most plastics

ESD acrylic sits in the static-dissipative band. Conductive material is not usually wanted for a window or a guard, because a fast discharge can itself damage a component; a controlled bleed is the objective.

Where it is required

  • Windows and guards on electronics assembly cells, where bare boards pass behind them.
  • Covers and doors on test fixtures that open over a populated board.
  • Totes, trays and carriers that hold boards or components.
  • Machine enclosures in a controlled ESD area, where a standard panel would be a charged surface next to the work.
  • Workstation screens and dividers in a certified ESD workstation.

Where a panel is outside the ESD-protected area, or where no bare components are exposed, standard acrylic is fine and costs far less.

What ESD acrylic costs and how it behaves

  • Typically 2.5 to 3 times the price of standard cast acrylic, and it is ordered in rather than stocked.
  • Slightly less clear than standard acrylic, because the additive that provides conductivity also scatters a little light. Usually acceptable for a guard, less so for a display.
  • Available in clear and in a few tints; the range is much narrower than standard acrylic.
  • Machines similarly, though some grades are more notch-sensitive and want a slightly different drilling setup.

Cleaning is where ESD panels fail

An ESD surface works by a thin conductive layer or a dispersed additive. An ordinary glass cleaner leaves a film that insulates it, and the panel quietly stops being dissipative while still looking correct. This is the most common and least visible failure in service.

  • Use an ESD-safe cleaner, specified by the sheet manufacturer.
  • Do not use household glass cleaner, furniture polish or any product with a wax or silicone.
  • Do not use abrasive pads, which remove the conductive surface.
  • Re-test periodically with a surface resistance meter; visual inspection proves nothing.

A panel that has been cleaned with the wrong product, or abraded, cannot be restored by cleaning it again. It has to be replaced, which is why the cleaning product belongs in the installation handover.

How to specify it

  • MATERIAL: STATIC-DISSIPATIVE PMMA, SURFACE RESISTIVITY 10^6–10^9 Ω/sq
  • SUPPLY TEST REPORT FOR THE SHEET BATCH
  • CLEANING: ESD-SAFE CLEANER ONLY (name the product, or state the prohibition)
  • NO ABRASIVE CLEANING; RE-TEST SURFACE RESISTANCE AT INSTALLATION

Documentation

We supply the sheet manufacturer test report for the batch, stating the resistivity range and the test method. What we cannot do is certify the performance of an installed system: ESD protection depends on the grounding, the flooring, the operator and the whole workstation, and the panel is one element of it. Where a site needs certification, that is done by an ESD auditor against the relevant standard.

Questions this article answers

No. Standard PMMA is an insulator and holds charge. Anti-static treatments and coatings exist but are temporary; a genuine static-dissipative sheet is a different product with a documented resistivity.

With a surface resistance meter, following the standard test method for the material. A visual check tells you nothing, and a panel that has been cleaned with the wrong product can look perfect and be insulative.

It can, but it is slightly less clear and considerably more expensive. Unless the display is inside an ESD-protected area, standard acrylic is the better choice.

A static-dissipative panel bleeds charge to the frame if the fixing is conductive. Where the panel is isolated by plastic washers it has nowhere to bleed to, which is a detail to agree with the ESD auditor.

No. Conductive and dissipative surfaces are not repairable in the field. A damaged panel is replaced.

Specifying and then verifying an ESD part

ESD is the one property where a part can pass on the day of delivery and fail six months later without anybody touching it wrongly. The reason is that two families of material behave completely differently, and only one of them is stable.

TypeResistivityBehaviour over timeWhen to choose it
Surface-coated10^6–10^9 ohms Decays with wiping, typically 6–12 monthsLow handling, short-life fixtures, cost-sensitive
Volume-conductive10^4–10^6 ohms Stable for the life of the partDaily-wiped trays, production line fixtures
Standard PMMA> 10^14 ohms Holds several kV after a wipeNever, near a bare board

Verification is where specifications go wrong. A resistivity figure without a test method is not a specification: surface resistivity measured with a concentric ring probe at 500 V and 23 percent RH gives a different number from a point-to-point measurement at 12 percent RH, and both are legitimate readings. Write the method, the electrode geometry and the humidity into the drawing note, or accept that two labs will disagree.

In service, the two things that destroy an ESD property fastest are abrasion and solvent. A tray cleaned with an IPA wipe is fine; the same tray scrubbed with an abrasive pad loses its surface layer and its conductivity together. That is the practical argument for volume-conductive sheet on anything handled daily — not the resistivity number, but the fact that the number does not depend on a coating that can be worn off.

Tell us whether bare boards pass the panel

That single fact decides whether you need ESD sheet at three times the price, or standard acrylic at a fraction of it.

WhatsApp